Fireplace mantel plans
The good mantelpiece – is not simple. Fireplace mantel plans were perfected for centuries, it – the fruit of thought thousands of stove-makers and modern scientific workings out.
When buying a fireplace models in the online store, we always recommend customers to order professional installation of the fireplace, because this work requires strict performance of fire protection regulations and big practical experience.
At the bottom on the figure there is a fireplace mantel plans.
When installing the furnace should strictly adhere to the installation instructions and installation, attached to each model furnace.
The fireplace mantel plans constructed with observance of general safety rules
1. Required foundation or concrete floor;
2. The air intake;
3. Delivery of fresh air (a minimum of 50 sm2);
4. Thermo insulated wall adjoining the fireplace;
5. Ventilated space, the transition air of convection;
6. Insulation, rigid sheet of aluminum;
7. Connection pipe made of a material:
- Cast iron with a thickness of 2-2.5 mm;
- Galvanized sheet with a thickness of 0.7 mm;
- Stainless steel sheet with a thickness of 0.5 mm.
8. Flue block door (It gives you access to the connecting pipe, on figure fireplace mantel plans is very clearly visible.);
9. Flue block from a fire-resistant material;
10. Distributive grid of a flue block (fixed in 35 cm from a ceiling);
11. Flue block baffle plate (a false ceiling from a fire-resistant material);
12. Grids of distribution of warm air;
13. Connecting elements (spigot-and-socket joints a minimum of 45 mm);
14. Reinforced Insulation Chimney: a maximum of 60° C on the outer partitions;
15. Admissible skews. Presence no more than two skews is admissible: corresponding corners in a vertical plane should not exceed 46° for smoke-ducts in height to 5м and 21° for higher designs.
16. In inaccessible places outside wall temperature of the flue pipe must not exceed 75° C.
17. The outer part of the fireplace chimney should be isolated from rainwater. The eminence of smoke pipes over a roof should be:
- Not less than 650 mm over a flat roof;
- Not less than 650 mm over the fad of a roof or a barrier wall at a pipe arrangement on distance to 1.5 m from the fad or a barrier wall;
- Not less than 650 mm above the ventilation ducts located near;
- Not below the ridge of the roof or parapet at the location of the chimney at a distance of 1.7 to 3.2 m from the ridge or parapet;
18. Fireplace chimney should be protected from the rain (Please, before you install good look at fireplace mantel plans.).